projects:blinker:work_logs:6_power_consumption_testing
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revision | |||
projects:blinker:work_logs:6_power_consumption_testing [2022/03/07 04:41] – tjhowse | projects:blinker:work_logs:6_power_consumption_testing [2022/03/07 04:47] (current) – tjhowse | ||
---|---|---|---|
Line 80: | Line 80: | ||
</ | </ | ||
- | Over 30000 seconds we get 233µW. At an average of 1.875V that gives us 124µA. The rated leakage current of the Zener is 120µA at 1v, so this seems reasonable. Once the full compliment of six 40-Farad caps are installed we should get a runtime of around 6 days. These numbers are all very rough, and treat a pretty non-linear curve as linear, but they should be approximately close. | + | Over 30000 seconds we get 233µW. At an average of 1.875v that gives us 124µA. The rated leakage current of the Zener is 120µA at 1v, so this seems reasonable. Once the full compliment of six 40-Farad caps are installed we should get a runtime of around 6 days. These numbers are all very rough, and treat a pretty non-linear curve as linear, but they should be approximately close. |
===== Video ===== | ===== Video ===== |
projects/blinker/work_logs/6_power_consumption_testing.1646628070.txt.gz · Last modified: 2022/03/07 04:41 by tjhowse